RMP Motion Controller
10.6.3
APIs
, concepts, guides, and more
Community
Support
Contact
◆
AmpFaultTriggerStateSet()
void AmpFaultTriggerStateSet
(
bool
state
)
Description:
AmpFaultTriggerStateSet sets the trigger state of the Amp Fault input.
Parameters
state
1 = triggers on active high signal, 0 = triggers on active low signal.
Part of the
Limits and Action Configuration
method group.
Sample Code:
Axis: Configuration
const
double
AMP_FAULT_DURATION_TIME = 1;
//value in seconds
// SET
axis.
AmpEnableSet
(
false
);
// Disable the amp
axis.
AmpFaultActionSet
(
RSIAction
.RSIActionABORT);
// Set the action that will occur when there is an amp fault.
axis.
AmpFaultTriggerStateSet
(
false
);
//Set the state of the amp fault.
axis.
AmpFaultDurationSet
(AMP_FAULT_DURATION_TIME);
//Set the duration required before the Amp Fault event triggers.
// GET
var isEnabled = axis.
AmpEnableGet
();
var faultAction = axis.
AmpFaultActionGet
();
var faultTriggerState = axis.
AmpFaultTriggerStateGet
();
var faultDuration = axis.
AmpFaultDurationGet
();
RapidSetup:
Go to axis screen->Limits & Actions. In the image below, AmpFaultTriggerStateSet sets the trigger state shown in the Amp Fault box. It currently triggers on a HIGH because the "High" checkbox is checked.
See also
AmpFaultTriggerStateGet
Examples
AxisConfig.cs
,
AxisConfiguration.cpp
,
PhantomAxis.cpp
, and
SampleAppsHelper.h
.
RSI
RapidCode
Axis
Generated by
1.10.0